Physical Review · 1968 · 21 citations · 6 references
EngineeringPhysicsNuclear PhysicsRadiation DetectionRadiation MeasurementDetector SystemsHeavy-ion PhysicsRadiation Detection PrinciplesRadiation DetectorsEnergy Loss AnalysisEnergy Loss DetectionEnergy Loss ProcessesHeavy Ion Stopping PowerProton Stopping PowerStopping Cross SectionSurface Barrier Detectors
An experiment employing a new method of measuring stopping power at low energies is described, and results are given for protons on gold. Values of $\frac{\mathrm{dE}}{\mathrm{dx}}$ for protons on gold have been obtained from measurements of the reponse of a silicon surface-barrier detector, covered with a surface layer of gold, to protons of energy below 50 keV. The response of the detector to $\mathrm{H}_{2}^{}{}_{}{}^{+}$ and $\mathrm{H}_{3}^{}{}_{}{}^{+}$ ions in the same energy range has been used to determine backscattering cross sections for protons on gold.
6
Passage of Heavy Particles through Matter
Samuel K. Allison, S. D. Warshaw · Reviews of Modern Physics · 1953 · 292 citations
Stopping Cross Section of Solids for Protons, 50-600 kev
M. Bader, R.E. Pixley, F. S. Mozer et al. · Physical Review · 1956 · 121 citations