Publication | Open Access
MRI of the thorax during whole‐body MRI: Evaluation of different MR sequences and comparison to thoracic multidetector computed tomography (MDCT)
67
Citations
20
References
2008
Year
Pulmonary MRI is feasible as part of a whole-body MRI protocol. In our study, STIR images achieved high accuracy compared to chest MDCT for pulmonary lesions of 3 mm in size or larger.