Medical Physics · 2009 · 72 citations · 45 references
MedicineRadiologyBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyBreast Cancer ImagingBreast Density AssessmentBreast ImagingMammography PhysicsBreast Composition AnalysisBreast Tissue ImagingDense Breast ImagingFibroglandular Tissue QuantificationFull-field Digital MammographyMammographyMeasures Of ShapeSensitivity
PURPOSE: Mammography has a low sensitivity in dense breasts due to low contrast between malignant and normal tissue confounded by the predominant water density of the breast. Water is found in both adipose and fibroglandular tissue and constitutes most of the mass of a breast. However, significant protein mass is mainly found in the fibroglandular tissue where most cancers originate. If the protein compartment in a mammogram could be imaged without the influence of water, the sensitivity and specificity of the mammogram may be improved. This article describes a novel approach to dual-energy mammography, full-field digital compositional mammography (FFDCM), which can independently image the three compositional components of breast tissue: water, lipid, and protein. METHODS: Dual-energy attenuation and breast shape measures are used together to solve for the three compositional thicknesses. Dual-energy measurements were performed on breast-mimicking phantoms using a full-field digital mammography unit. The phantoms were made of materials shown to have similar x-ray attenuation properties of the compositional compartments. They were made of two main stacks of thicknesses around 2 and 4 cm. Twenty-six thickness and composition combinations were used to derive the compositional calibration using a least-squares fitting approach. RESULTS: Very high accuracy was achieved with a simple cubic fitting function with root mean square errors of 0.023, 0.011, and 0.012 cm for the water, lipid, and protein thicknesses, respectively. The repeatability (percent coefficient of variation) of these measures was tested using sequential images and was found to be 0.5%, 0.5%, and 3.3% for water, lipid, and protein, respectively. However, swapping the location of the two stacks of the phantom on the imaging plate introduced further errors showing the need for more complete system uniformity corrections. Finally, a preliminary breast image is presented of each of the compositional compartments separately. CONCLUSIONS: FFDCM has been derived and exhibited good compositional thickness accuracy on phantoms. Preliminary breast images demonstrated the feasibility of creating individual compositional diagnostic images in a clinical environment.
45
Ahmedin Jemal, Rebecca L. Siegel, Elizabeth Ward et al. · CA A Cancer Journal for Clinicians · 2008 · 10.2K citations · Full text
Solvent content of protein crystals
Brian W. Matthews · Journal of Molecular Biology · 1968 · 8K citations
John A. Professor Kanis, L. Joseph Melton, Claus Christiansen et al. · Journal of Bone and Mineral Research · 1994 · 3.9K citations
REDUCTION IN MORTALITY FROM BREAST CANCER AFTER MASS SCREENING WITH MAMMOGRAPHY
Làszló Tabár, Ahmed Z. Gad, Lars Holmberg et al. · The Lancet · 1985 · 1.8K citations