Concepedia

Publication | Closed Access

RADON CONCENTRATIONS IN ELEMENTARY SCHOOLS IN KUWAIT

25

Citations

18

References

2006

Year

Abstract

Measurements of indoor radon concentrations were performed in 25 classrooms in the capital city of Kuwait from September 2003 to March 2004 using track etch detectors. The investigation was focused on area, ventilation, windows, air conditioners, fans, and floor number. All the schools have nearly the same design. Mean indoor radon concentration was higher for case subjects (classrooms) than for control subjects (locations in inert gas, p < 0.001). The mean alpha dose equivalent rate for case subjects, 0.97 +/- 0.25 mSv y, was higher than the radiation dose equivalent rate value of control subjects, 0.43 +/- 0.11 mSv y. The average radon concentrations were found to be 16 +/- 4 Bq m for the first floor and 19 +/- 4.8 Bq m for the second floor after subtraction of the control. These values lead to average effective dose equivalent rates of 0.40 +/- 0.10 and 0.48 +/- 0.12 mSv y, respectively. The equilibrium factor between radon and its progeny was found to be 0.6 +/- 0.2.

References

YearCitations

Page 1