Emergency repair of severely damaged reinforced concrete columns using active confinement with shape memory alloys

66

Citations

9

References

2011

Year

Abstract

This experimental study focuses on investigating the feasibility of utilizing spirals made of shape memory alloys (SMAs) to conduct emergency repair on severely damaged reinforced concrete (RC) columns. The thermally triggered shape memory feature of SMAs is sought in this study, to apply active confinement pressure on the column's damaged region. Two severely damaged 1/3-scale RC columns are repaired using the proposed technique and tested under a quasi-static lateral cyclic load. The repair of each column is conducted in less than 15 h, and the columns are tested 24 h after the starting of the repair process. The experimental results show that the new repair technique is successful in either fully restoring the as-built lateral strength, stiffness, and flexural ductility of the columns or making them even better. The efficacy of the proposed repair technique is mainly attributed to the ability of the SMA spirals to apply and maintain active confining pressure on the damaged region of the columns, which increases the strength of the already damaged concrete and delays its damage.