Journal of Applied Physics · 2000 · 30 citations · 8 references
Natural SciencesElectrical EngineeringPhysicsElectromagnetismMicrowave EngineeringThin FilmsMagnetic CharacterizationMagnetic Thin FilmsMicrowave MaterialsMicrowave MeasurementsMicrowave Transmission LinesThin Film Magnetic PropertiesBroadband MeasurementCharacterization Of Microwave MaterialsMagnetic PermeabilityMagnetic Property CharacterizationMagnetic Property MeasurementMetallic Thin FilmsPermeability MeasurementSensitivity
A new method to measure the microwave permeability of ferromagnetic thin film or microwires from 50 MHz up to 18 GHz is presented. In contrast with all previous permeameters based on perturbation techniques, our permeameter does not require any reference sample for calibration, which is a definite advantage, as it is very difficult to have a reference magnetic sample of known permeability. In our technique, a network analyzer detects the small perturbation of the impedance of a coaxial line cell loaded by the magnetic sample. Satisfactory sensitivity is achieved, even for magnetic volume fraction as low as 10−4. To assess the validity of this new technique, comparisons are performed with three other methods on different samples, in particular on ferromagnetic wires. It is shown that in the case of very soft magnetic materials, the shape of the sample affects the permeability measured with a conventional permeameter.
8
An improved permeameter for thin film measurements up to 6 GHz
D. Pain, M. Ledieu, O. Acher et al. · Journal of Applied Physics · 1999 · 134 citations