Visualization of Endolymphatic Hydrops in Ménière's Disease with Single-dose Intravenous Gadolinium-based Contrast Media using Heavily T2-weighted 3D-FLAIR

Shinji Naganawa, Masahiro Yamazaki, Hisashi Kawai, Kiminori Bokura, Michihiko Sone, Tsutomu Nakashima

Magnetic Resonance in Medical Sciences · 2010 · 188 citations · 10 references

DOIFull text

Open access

Concepts

Abstract

Heavily T(2)-weighted 3-dimensional fluid-attenuated inversion recovery (hT(2)W-3D-FLAIR) technique has been reported to be more sensitive than conventional 3D-FLAIR in detecting low concentrations of gadolinium-based contrast media (GBCM) in fluid. We applied hT(2)W-3D-FLAIR to visualize endolymphatic hydrops of Ménière's disease in 3 patients 4 hours after single-dose intravenous injection of GBCM and successfully visualized endolymphatic hydrops in either the cochlea or vestibule in all patients. This technique can be implemented in a clinical setting.

References

10