Environmental Science & Technology · 2010 · 48 citations · 17 references
EngineeringChemical EngineeringMechanical EngineeringAir PollutionCombustionFire ManagementBiomass Burning EmissionsCombustion AnalysisCombustion FundamentalsCombustion KineticsCombustion ProcessesNitrogen OxidesAir-fuel RatioAir-fuel Ratio EffectsBoiler CombustionCoal Combustion EmissionsCombustion CharacteristicsFurnace DesignGas Temperature DistributionMass Flux
Down-fired boilers used to burn low-volatile coals have high NO(x) emissions. To find a way of solving this problem, an overfire air (OFA) system was introduced on a 300 MW(e) down-fired boiler. Full-scale experiments were performed on this retrofitted boiler to explore the influence of the OFA ratio (the mass flux ratio of OFA to the total combustion air) on the combustion and NO(x) emission characteristics in the furnace. Measurements were taken of gas temperature distributions along the primary air and coal mixture flows, average gas temperatures along the furnace height, concentrations of gases such as O(2), CO, and NO(x) in the near-wall region and carbon content in the fly ash. Data were compared for five different OFA ratios. The results show that as the OFA ratio increases from 12% to 35%, the NO(x) emission decreases from 1308 to 966 mg/Nm(3) (at 6% O(2) dry) and the carbon content in the fly ash increases from 6.53% to 15.86%. Considering both the environmental and economic effect, 25% was chosen as the optimized OFA ratio.
17