Innovations Technology and Techniques in Cardiothoracic and Vascular Surgery · 2007 · 18 citations · 9 references
MedicineCardiologySurgeryCardiothoracic SurgeryDiagnostic ImagingDiagnostic RadiologyAortic SurgeryCardiac ImagingCardiac Valve SurgeryCardiovascular ImagingMagnetic Resonance ImagingMedical ImagingAnatomic FeasibilityAortic Valve ImagingBioprosthetic Heart ValvesBioprosthetic Valve ProsthesesFunctional ImagingIntraoperative Perfusion AssessmentReal-time Image GuidanceReal-time Imaging
OBJECTIVE: : The principal limitations of percutaneous techniques to replace the aortic valve are detailed visualization and durable prostheses. We report the feasibility of using real-time magnetic resonance imaging (MRI) to provide precise anatomic detail and visual feedback to implant a proven bioprosthesis. METHODS: : Twelve domestic pigs were anesthetized, and, through a minimally invasive approach using real-time MRI guidance, underwent aortic valve replacement. This was accomplished on the beating heart by using a commercially available bioprosthesis. MRI was used to precisely identify the anatomic landmarks of the aortic annulus, coronary artery ostia, and the mitral valve leaflets. Additional intraoperative perfusion, flow velocity, and functional imaging were used to confirm adequacy of placement and function of the valve. RESULTS: : Under real-time MRI, multiple oblique planes were prescribed to delineate the anatomy of the native aortic valve and left ventricular outflow track. Enhanced by the use of an active marker wire, this imaging allowed correct placement and orientation of the valve. Through a transapical approach, a series of bioprosthetic aortic valves (21 to 25 mm) were inserted. The time to implantation after the placement of the trocar to deployment of the valve was less than 90 seconds. The average procedure duration was less than 40 minutes CONCLUSIONS: : Real-time MRI provides excellent anatomic detail and intraoperative assessment that permits placement of durable valve prostheses on the beating heart without the limitations of percutaneous approaches.
9
Percutaneous Transcatheter Implantation of an Aortic Valve Prosthesis for Calcific Aortic Stenosis
Alain Cribier, Hélène Eltchaninoff, Assaf Bash et al. · Circulation · 2002 · 3.2K citations · Full text
Medicine, Cardiology, Surgery +16
Minimally Invasive Valve Operations
Delos M. Cosgrove, Joseph F. Sabik, José Navia · The Annals of Thoracic Surgery · 1998 · 380 citations · Full text
One Thousand Minimally Invasive Valve Operations
Lawrence H. Cohn, Daniel Unić, Sary F. Aranki et al. · Annals of Surgery · 2004 · 272 citations · Full text
Medicine, Cardiology, Surgery +17