Fire Safety Science · 1986 · 24 citations · 1 references
EngineeringArchitectural EngineeringFire Protection EngineeringStructural AnalysisStructural EngineeringFire PreventionFire SafetyFire TestingFire-resistant MaterialsStructural Fire EngineeringFire PerformanceFire ResistanceFire Resistance AssessmentFire-resistant ConcreteReinforced ConcreteStructural Fire ProtectionStructural Fire ResponseThermal Expansion
Experimental and theoretical studies were carried out on the effect of restraint on the fire resistance of reinforced concrete columns. Two tests were carried out on axially loaded columns fully restrained against thermal expansion. Both experimental and theoretical studies indicate that full restraint of axial thermal expansion has little influence on the fire performance of the columns. The maximum stresses in a fully restrained column at the time that the restraining load is maximum, are considerably lower than those at the time of failure of the column.
1