Journal of Laparoendoscopic & Advanced Surgical Techniques · 1999 · 47 citations · 16 references
MedicineSurgeryGeneral SurgeryLaparoscopic UrologyVascular SurgeryLaparoscopic SurgeryMinimally Invasive SurgerySurgical ComplicationsSurgical SafetyComplication Rate AnalysisComplication Rate MeasurementLaparoscopic-assisted SurgeryPort-site ComplicationsTrocar Placement
Blind insertion of the Veress needle and of the first trocar is a significant cause of laparoscopic surgery complications. Despite this risk, the closed technique is still more popular than the open one. The authors retrospectively evaluated 1006 consecutive laparoscopic operations in which Hasson's technique was routinely performed. The overall complication rate was 2.2%, but the vast majority of complications occurred during the first 50 cases (6% vs. 1.9%). They conclude that after a learning phase of about 50 cases, Hasson's technique is a quick and safe procedure.
16
A modified instrument and method for laparoscopy
H.M. Hasson · American Journal of Obstetrics and Gynecology · 1971 · 588 citations
Medicine, Gynecology, Surgery +12
How to prevent complications of open laparoscopy.
A J Penfield · PubMed · 1985 · 139 citations
Medicine, Gynecology, Surgery +10