IEEE Transactions on Power Apparatus and Systems · 1980 · 19 citations · 3 references
EngineeringElectrical EngineeringMaterials ScienceMaintenance EngineeringMechanical Behavior Of MaterialsThermal AnalysisDielectricsInsulation MaterialsInsulation SystemsThermal InsulationThermal Properties Of MaterialsThermal StressesDielectric ConstantDielectric StrengthDielectric Strength TestingElectrical Power ConductorsFailure Mode InvestigationInsulation DurabilityMetallic ConductorsTransformer Insulation
Model structures representative of power transformer conductors and metallic components have been tested at elevated hot-spot temperatures to simulate operation at overloads. Three different types of cellulosic insulation in contact with hot-spots evolved visible gas bubbles at temperatures as low as 140°C, while hot metal in contact with oil alone produced no visible gas bubbles up to approximately 350°C. The dielectric strength of insulated conductors was observed to deteriorate moderately at temperatures in the 100°C to 150 °C range, but more rapidly at temperatures above 150°C. The experimental results have been analyzed and are discussed with relation to their potential significance to transformer loading practices.
3
Thermal decomposition of natural cellulose in vacuo
Eleanor Murphy · Journal of Polymer Science · 1962 · 65 citations