Review of Scientific Instruments · 2010 · 92 citations · 12 references
Natural SciencesNuclear EngineeringPhysicsOpticsPhotonicsPlasma PhysicsLaser OpticsLaser PhysicsLaser-plasma InteractionsOptical InstrumentationAccuracyBackscatter RadiationHohlraum PhysicsLaser DiagnosticsLaser Heating Of PlasmasLasersSensor Accuracy
Backscattered light via laser-plasma instabilities has been measured in early NIF hohlraum experiments on two beam quads using a suite of detectors. A full aperture backscatter system and near backscatter imager (NBI) instrument separately measure the stimulated Brillouin and stimulated Raman scattered light. Both instruments work in conjunction to determine the total backscattered power to an accuracy of ∼15%. In order to achieve the power accuracy we have added time-resolution to the NBI for the first time. This capability provides a temporally resolved spatial image of the backscatter which can be viewed as a movie.
12
Symmetric Inertial Confinement Fusion Implosions at Ultra-High Laser Energies
S. H. Glenzer, B. J. MacGowan, P. Michel et al. · Science · 2010 · 361 citations
Design and modeling of ignition targets for the National Ignition Facility
S. W. Haan, S. M. Pollaine, J. D. Lindl et al. · Physics of Plasmas · 1995 · 353 citations