BMJ · 1986 · 27 citations · 5 references
Life SciencesInfectious DiseasesMicrobiologyBacteriologyDiagnostic MicrobiologyMedical MicrobiologyAntibiotic ResistanceAntimicrobial Susceptibility TestingBacterial InfectionsDiagnostic BacteriologyPathogen DetectionSexually Transmitted InfectionsAntibiotic Resistance ScreeningBacterial DetectionClinical Detection Of Beta-lactam ResistanceDetection SystemsEnterobacteriaceae DetectionExtended-spectrum Beta-lactamase Producing OrganismsExtended-spectrum Beta-lactamase ProductionExtended-spectrum Beta-lactamase-producing Organisms
<h3>Background and Aims:</h3> Clinical hospitals need to correctly identify extended spectrum β-lactamase (ESBL)-producing bacteria in infected patients to correctly treat the patient and avoid spreading antibiotic resistance. Kuwaiti hospitals use one laboratory test for detecting ESBL bacteria. This study evaluated whether that was sufficient to detect ESBL bacteria, and compared the Vitek system with other detection systems. <h3>Methods:</h3> (<i>Klebsiella pneumoniae</i>, <i>Escherichia coli</i>, <i>K oxytoca</i> and <i>Enterobacter cloacae</i>) were collected from five different Kuwaiti main hospitals, all of which were flagged as ESBL-positive by the Vitek 2 system. The isolates were retested by the Vitek 2 system, and were also tested by double disc diffusion (DDD), the disc approximation test, the E-test and the MicroScan system for the detection of ESBLs. <h3>Results:</h3> Retesting with the Vitek system revealed 100% compatibility with the results of the source hospitals. The MicroScan system, DDD, disc approximation test and E-test could detect ESBL in 199, 192, 178 and 205 isolates, respectively. <h3>Conclusions:</h3> Technically, the MicroScan and Vitek 2 systems were the least demanding method to detect ESBL as it is an integral part of the routine susceptibility test card. E-test strips were reliable but the most expensive of all techniques used. The DDD test and disc approximation, while relatively inexpensive, were technically subjective. The Vitek system may be very suitable in clinical laboratories, but would be better if accompanied with another test for detection of ESBL bacteria.
5
NON-STEROIDAL ANTI-INFLAMMATORY DRUGS AND BLEEDING PEPTIC ULCER
K W Somerville, Gail Faulkner, M. J. S. Langman · The Lancet · 1986 · 545 citations
IMPORTANCE OF THE MALE FACTOR IN CANCER OF THE CERVIX
D C Skegg, Paul Corwin, Charlotte Paul et al. · The Lancet · 1982 · 142 citations
Three years' experience in a sexual problems clinic.
John Bancroft, L. Stephen Coles · BMJ · 1976 · 117 citations · Full text
Sex, Culture, and Human Fertility: India and the United States
Moni Nag · Current Anthropology · 1972 · 43 citations