JAMA · 1976 · 89 citations · 15 references
PharmacyPhysiologyOccupational ToxicologyPulmonary Function TestingRegulatory ToxicologyCarbon MonoxideRespiratory Monitoring InstrumentsBlood Carbon Monoxide AnalysisCarbon Monoxide BiomarkersCarbon Monoxide DetectionCarbon Monoxide MeasurementCarbon Monoxide MonitoringElectrochemical Cell BiosensorsElectrochemical Cell SensingPortable Electrochemical Sensors
The analysis of expired breath with a portable electrochemical cell after carbon monoxide exposure provides a practical field method for the rapid estimation of carboxyhemoglobin. A fire fighter can collect and analyze his own breath sample for CO, an operation that requires 1 1/2 minutes. This simple technique has the accuracy necessary to determine compliance with the regulations governing occupational exposure to CO.
15
Carbon Monoxide Effect on Exercise-Induced Angina Pectoris
Wilbert S. Aronow · Annals of Internal Medicine · 1973 · 192 citations
Medicine, Cardiology, Physiology +16