Journal of Glaucoma · 2008 · 19 citations · 17 references
MedicineOphthalmologySurgeryAnterior SegmentOphthalmic SurgeryRefractive SurgeryCorneal AnatomyCorneal TopographyIntraocular Pressure MeasurementLaser In Situ KeratomileusisOcular BiometryPreoperative Refractive EvaluationCorneal Curvature MeasurementCorneal Shape ChangesCorneal Thickness AssessmentCorneal Thickness ChangesCorneal Topography AssessmentCorneal Topography ChangesIntraocular Pressure ReductionMean Curvature
PURPOSE: To determine the factors that lead to changes in intraocular pressure (IOP) measurements after laser-assisted in situ keratomileusis (LASIK) and their long-term stability. PATIENTS AND METHODS: Five hundred twenty-two myopic eyes and 296 hyperopic eyes were enrolled in the study. Pneumotonometry was used to measure IOP once in the preoperative stage and twice in the postoperative stage-1 month after the operation and 1 year later. Ultrasonic pachymetry was used to determine preoperative and intraoperative corneal thicknesses and axial length of the eye, whereas optical pachymetry was used in the preoperative stage and 1 month after surgery. Corneal topography was used to determine the preoperative and postoperative mean curvature of the anterior surface of the cornea over 3 and 5-mm diameter regions. Comparative statistical analysis of the retrospective data series was performed. RESULTS: A highly significant reduction of IOP readings is found after LASIK for both myopic and hyperopic eyes. The reduction is stable 1 year after LASIK. In the case of myopic eyes, the reduction has a highly significant linear correlation with the amount of tissue ablated in the central region of the cornea. CONCLUSIONS: Pneumotonometric IOP readings after LASIK are reduced, without recovering preoperative values even 1 year after surgery, because of flap cutting and tissue removal in the central region of the cornea. The contribution of flap cutting is estimated to be (1.6+/-0.8) mm Hg, whereas ablation contributes an additional (0.029+/-0.003) mm Hg/microm of removed tissue. This effect should be considered when evaluating the accuracy of IOP measurements in LASIK patients who are at risk for developing glaucoma.
17
The Ocular Hypertension Treatment Study
Michael A. Kass · Archives of Ophthalmology · 2002 · 3.7K citations · Full text
The Ocular Hypertension Treatment Study
Mae O. Gordon · Archives of Ophthalmology · 2002 · 2.6K citations
The relationship between glaucoma and myopia
Paul Mitchell, Fleur Hourihan, Jen Sandbach et al. · Ophthalmology · 1999 · 978 citations