Applied Optics · 2002 · 15 citations · 8 references
EngineeringBiomedical EngineeringElectrical EngineeringOptoelectronicsPhotonicsSensorsFiber OpticsInfrared InstrumentationInfrared SpectroscopyOptical FibersTemperature MeasurementTemperature SensorsInfrared Fiber OpticsInfrared RadiometryInfrared SensorsNoncontact MeasurementOptical ThermometryRadiometer DesignResponse TimeThermal Sensing
A fiber-optic radiometer is developed for accurate noncontact temperature measurements. Of compact and novel design, it is based on replacing the usual chopper with a simple shutter. The radiometer operates in a spectral range of 5-20 microm and uses a silver-halide IR-transmitting optical fiber. The radiometer has a temperature resolution of 0.1 degrees C, a time response of 200 ms, and a spatial resolution of approximately 1 mm. Theory, simulation, radiometer design and construction, and examples of experimental measurements are shown. The novel radiometer can be used in diverse applications in science, medicine, and industry.
8
Fibers for low-temperature radiometric measurements
A. Zur, Abraham Katzir · Applied Optics · 1987 · 35 citations
Mechanical and optical properties of silver-halide infrared transmitting fibers
Shaul Shalem, Alla German, N. Barkay et al. · Fiber & Integrated Optics · 1997 · 33 citations