The Journal of Urology · 2009 · 14 citations · 11 references
MedicineRadiologyUrologyDiagnostic ImagingDiagnostic RadiologyPediatric RadiologyComputed TomographyGenitourinary ImagingRenal ImagingScanning TechniquesUreteral ImagingUrinary Stone SurgeryBladder Stones ImagingMulti-detector Computed TomographyRenal CalculiRenal Stone DetectionRenal Stone ImagingTomographyUreteral Stone ImagingUreteral Stone Management
PURPOSE: We determined the effect of reconstructed section width on sensitivity and specificity for detecting renal calculi using multidetector row computerized tomography. MATERIALS AND METHODS: Three to 5 renal stones 2 to 4 mm in size were randomly placed into 14 human cadaveric kidneys and scanned by 16-row detector computerized tomography at 1.25 mm collimation and identical scanning parameters. After acquisition images were reconstructed with a section width of 1.25, 2.5, 3.75 and 5.0 mm, and reviewed independently by 2 blinded radiologists. Comparisons of sensitivity and specificity between different section widths were assessed with the McNemar test and Cochran's Q statistics. RESULTS: Specificity was not significantly affected by section width (94.6% to 97.7%). In contrast, sensitivity increased as stone size increased and as section width decreased. Sensitivity to detect all stones was 80.7%, 80.7%, 87.7% and 92.1% for 5.0, 3.75, 2.5 and 1.25 mm section widths, respectively. Interobserver agreement for stone detection was excellent (kappa 0.858). Although the 2.0 mm stone detection rate improved with thinner section widths (79.4% vs 52.9% for 1.25 vs 5.0 mm, p = 0.004), stones greater than 2.0 mm were similarly detected at different slice selections (p = 0.056 to 0.572). CONCLUSIONS: Independent of other scanning parameters reconstruction section width influences the ability to detect small renal calculi. It must be considered when creating computerized tomography protocols.
11
Acute flank pain: comparison of non-contrast-enhanced CT and intravenous urography.
Robert C. Smith, Arthur T. Rosenfield, K A Choe et al. · Radiology · 1995 · 675 citations
Diagnosis of acute flank pain: value of unenhanced helical CT.
Robert C. Smith, M Verga, Shirley McCarthy et al. · American Journal of Roentgenology · 1996 · 585 citations
Low-Dose Unenhanced Multidetector CT of Patients with Suspected Renal Colic
Denis Tack, S Sourtzis, Isabelle Delpierre et al. · American Journal of Roentgenology · 2003 · 224 citations
Medicine, Nephrology, Radiology +15
K. C. SAW, James A. McAteer, Ashish G. Monga et al. · American Journal of Roentgenology · 2000 · 198 citations