Electrochemical evaluation of glucose oxidase immobilized by different methods
25
Citations
2
References
1975
Year
Chemical EngineeringEngineeringBiochemistryBiosensing SystemsBioelectrochemistryBioelectronicsEnzyme ElectrodeBiochemical EngineeringBiomedical DevicesImmobilized EnzymeElectroanalytical SensorPlatinum ScreenElectrochemical CellEnzyme ImmobilizationElectrode Reaction MechanismElectrochemical EvaluationElectrochemistry
Abstract Glucose oxidase electrodes were constructed on a platinum screen using polyacrylamide gel, glutaraldehyde crosslinking, and glutaraldehyde crosslinking with +0.04 volts dc on the platinum screen as the methods of enzyme immobilization. The electrodes were evaluated in an electrochemical cell for the oxidation of glucose at the enzyme electrode and the reduction of oxygen at a platinum auxiliary electrode, using constant current voltametry or under external load operation. The method of immobilization affected the extrapolated opencircuit potential as well as the half‐cell potential and the steady current under external load operation. The charged glutaraldehyde electrode gave the best current performance; however, the small output (microamps) indicated that major problems in electron transfer from an enzyme catalyst to an external circuit must be resolved before such electrodes can be used in practical application.