Respiratory Research · 2007 · 18 citations · 14 references
PharmacyPharmacokineticsPharmacologyMolecular ImagingPharmacokinetics Of Anticancer AgentsPulmonologyFluorescence SpectroscopyInhalation Dosage FormsInhalation Drug DeliveryLung CancerPhotodynamic TherapyPulmonary PharmacokineticsBronchial DiseaseBronchial DysplasiaBronchoscopyFluorescence In TissueInhaled AdministrationInhaled Drug PharmacokineticsModerate DysplasiaTherapeutic Bronchoscopy
BACKGROUND: In the diagnosis of early-stage lung cancer photosensitizer-enhanced fluorescence bronchoscopy with inhaled 5-aminolevolinic acid (5-ALA) increases sensitivity when compared to white-light bronchoscopy. This investigation was to evaluate the in vivo tissue pharmacokinetics of inhaled 5-ALA within the bronchial mucosa in order to define the time optimum for its application prior to bronchoscopy. METHODS: Patients with known or suspected bronchial carcinoma were randomized to receive 200 mg 5-ALA via inhalation 1, 2, 3, 4 or 6 hours before flexible fluorescence bronchoscopy was performed. Macroscopically suspicious areas as well as areas with visually detected porphyrin fluorescence and normal control sites were measured spectroscopically. Biopsies for histopathology were obtained from suspicious areas as well as from adjacent normal areas. RESULTS: Fluorescence bronchoscopy performed in 19 patients reveals a sensitivity for malignant and premalignant changes (moderate dysplasia) which is almost twice as high as that of white-light bronchoscopy, whereas specificity is reduced. This is due to false-positive inflammatory lesions which also frequently show increased porphyrin fluorescence. Malignant and premalignant alterations produced fluorescence values that are up to 5 times higher than those of normal tissue. According to the pharmacokinetics of porphyrin fluorescence measured by spectroscopy, the optimum time range for 5-ALA application is 80-270 min prior to fluorescence bronchoscopy, with an optimum at 160 min. CONCLUSION: According to our results we propose inhalation of 5-ALA 160 min prior to fluorescence bronchoscopy, suggesting that this time difference provides the best tumor/normal tissue fluorescence ratio.
14
Localization of Bronchial Intraepithelial Neoplastic Lesions by Fluorescence Bronchoscopy
Stephen Lam, Timothy C. Kennedy, Michael Unger et al. · CHEST Journal · 1998 · 573 citations
Autofluorescence of normal and malignant bronchial tissue
Jaclyn Y. Hung, Stephen Lam, Jean LeRiche et al. · Lasers in Surgery and Medicine · 1991 · 383 citations
Medicine, Cancer Biology, Oncology +17
The international system for staging lung cancer
Clifton F. Mountain · Seminars in Surgical Oncology · 2000 · 217 citations
Detection and localization of early lung cancer by fluorescence bronchoscopy
Stephen Lam, Calum MacAulay, Jean LeRiche et al. · Cancer · 2000 · 187 citations · Full text