Implementing the virtual output impedance concept in a three phase system utilising cascaded PI controllers in the dq rotating reference frame for microgrid inverter control

Christopher N. Rowe, T. J. Summers, R.E. Betz, Tim Moore, Christopher D. Townsend

2013 · 26 citations · 12 references

Concepts

Abstract

This paper extends research on single phase microgrids [1] to implement a Virtual Output Impedance (VOI) in a three phase system utilising cascaded PI voltage and current control in the Rotating Reference Frame (RRF). The paper proposes two methods for the selection of VOI values; a selection surface and a summation approach. SABER simulations and dSPACE hardware results are provided for a two inverter microgrid to validate the control scheme and selection techniques.

References