Study on the dielectric characteristics of DC XLPE cables

Sumitoshi Ogata, Yuichi Maekawa, Kazuki Terashima, R. Okiai, Shigeo Yoshida, Hiroshi Yamanouchi, S. Yokoyama

IEEE Transactions on Power Delivery · 1990 · 13 citations · 3 references

Concepts

Abstract

The DC characteristics of XLPE (crosslinked polyethylene) power cables were investigated. Cables with an insulation thickness of 2.5 mm, 9 mm, and 13 mm using either XLPE or conductive-inorganic-filled XLPE (XL-A) were manufactured, and four kinds of breakdown tests (DC, polarity reversal, impulse, and superposing opposite polarity impulse on DC prestress) were performed. A 250 kV, XL-A cable (20 mm thickness) was designed and manufactured using the results. The test results show that the XL-A cable possesses much better DC breakdown characteristics than the XLPE cable and is adequate for use in DC cables.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">&gt;</ETX>

References

3