JAMA Surgery · 2014 · 41 citations · 15 references
MedicineRadiologySurgeryCardiothoracic SurgeryDiagnostic ImagingVascular SurgeryAortic DiseaseAortic Dissection ManagementAortic ImagingAortic SurgeryThoracic SurgeryAbdominal Aorta ImagingAcute Aortic DissectionAortic Volume QuantificationAscending Aorta ImagingChronic Aortic DissectionEndovascular Aortic Repair ImagingRetrospective Record ReviewType B Aortic Dissection
IMPORTANCE: Thoracic endovascular aortic repair (TEVAR) is used in the treatment of type B aortic dissections. Information related to aortic morphologic findings and the condition of the abdominal aorta after TEVAR is limited. OBJECTIVE: To analyze aortic morphologic findings after TEVAR for type B aortic dissections. DESIGN, SETTING, AND PARTICIPANTS: After a retrospective database review, the data for 30 patients who underwent TEVAR from January 1, 2007, through December 31, 2013, for type B aortic dissection were analyzed. Imaging software was used to calculate aortic diameters and volumes of the aorta on computed tomography (CT) or magnetic resonance imaging (MRI). Mean follow-up was 14.4 months. INTERVENTIONS: We performed TEVAR to cover proximal thoracic aorta tears in patients who underwent acute or chronic type B aortic dissections. MAIN OUTCOMES AND MEASURES: Aortic morphologic findings of pre-TEVAR CT or MRI were compared with the most recent findings of post-TEVAR CT or MRI. Frequency of thoracic false lumen thrombosis (FLT) and false lumen patency (FLP) was determined and the effect on post-TEVAR aortic morphologic findings analyzed. RESULTS: Mean (SD) TEVAR increased true lumen diameter (19.50 [6.92] mm to 31.19 [5.36] mm, P < .001) and volume (77.92 [41.70] mL to 166.95 [69.69] mL, P < .001) and decreased false lumen diameter (29.77 [12.55] mm to 21.92 [12.05] mm, P = .001) on post-TEVAR CT or MRI when compared with pre-TEVAR scans. Seventy percent of patients experienced thoracic FLT; 30% had FLP. True lumen volume expansion and false lumen volume regression occurred in patients with FLT (82.07 [46.95] mm to 180.55 [77.99] mm, P < .001 and 161.84 [106.36] mm to 115.76 [140.77] mm, P = .002, respectively) and FLP (68.23 [21.43] mm to 128.22 [21.46] mm, P < .001 and 238.64 [174.00] mm to 198.93 [120.46] mm, P = .04, respectively). Patients with FLT had increased true lumen diameter (15.67 [6.43] mm to 26.13 [7.62] mm, P < .001) and volume (54.86 [30.52] mL to 88.08 [41.07] mL, P = .001) in the abdominal aorta after TEVAR, with no change in total abdominal aortic volume (161.94 [70.12] mL vs 160.36 [82.11] mL, P = .90). Total abdominal aortic volume significantly increased in patients with thoracic FLP (187.24 [89.88] mL to 221.41 [82.64] mL, P = .02). CONCLUSIONS AND RELEVANCE: Favorable aortic remodeling of the thoracic aorta occurs after TEVAR for type B aortic dissections in patients with thoracic FLT and FLP. However, failure to achieve thrombosis of the thoracic false lumen negatively influences aortic morphologic findings of the contiguous abdominal aorta.
15
Endovascular Stent–Graft Placement for the Treatment of Acute Aortic Dissection
Michael D. Dake, Noriyuki Kato, R. Scott Mitchell et al. · New England Journal of Medicine · 1999 · 1.3K citations · Full text
Medicine, Cardiology, Surgery +12
Endovascular Repair of Type B Aortic Dissection
Christoph Nienaber, Stephan Kische, Hervé Rousseau et al. · Circulation Cardiovascular Interventions · 2013 · 1.1K citations · Full text
Long-Term Survival in Patients Presenting With Type B Acute Aortic Dissection
Thomas T. Tsai, Rossella Fattori, Santi Trimarchi et al. · Circulation · 2006 · 761 citations · Full text