Magnetic Resonance in Medicine · 1994 · 924 citations · 21 references
MedicineNeurologyNeuroscienceBiomedical ImagingDiagnostic ImagingNeuropathologyBrain ImagingDemyelinating DisordersMagnetic Resonance ImagingMagnetic Resonance Imaging PhysicsMagnetic Resonance Signal FormationMultiple SclerosisBrain Microstructure ImagingMagnetic RelaxationMagnetic Resonance Relaxation TimesMagnetic SheathsMultiple Sclerosis PathologyMyelin FormationNuclear Magnetic Resonance RelaxationWhite Matter Imaging
We exploit the intrinsic difference in magnetic resonance spin-spin relaxation time, T2, between water associated with myelin sheaths and water in other central nervous system tissue in order to measure myelin water content within any region of an image or to generate indirectly a myelin map of the brain. In normal volunteers, myelin water maps give the expected myelin distribution. In multiple sclerosis patients, lesions exhibit different myelin water contents providing insight into the demyelination process unavailable from conventional magnetic resonance images. In vivo myelin measurement has important applications in the clinical management of multiple sclerosis and other white matter diseases.
21
Relaxometry of brain: Why white matter appears bright in MRI
S. H. Koenig, R. D. Brown, Marga Spiller et al. · Magnetic Resonance in Medicine · 1990 · 305 citations