Journal of Liquid Chromatography & Related Technologies · 2007 · 17 citations · 5 references
PharmacyChemistryPharmaceutical AnalysisAnalytical ChemistryChromatographic AnalysisSeparation ProcessesAnalytical ChromatographyChromatographic SeparationChromatographyLiquid ChromatographyMobile Phase OptimizationStationary Phase ChemistryAnalysis Time OptimizationChiral Mobile PhasesChromatographic Drug AnalysisChromatographic SelectivityDrug Retention TimeReversed-phase Mobile PhasesSeparation FactorSolvent Optimization
Abstract In this paper optimal conditions of chromatographic determination and separation of hexabenzyldigermoxane and hexabenzyldigermanium by the HPLC method are presented. These compounds cause numerous difficulties in chromatographic processes, because they can be retarded on chromatographic columns and are characterized by long retention times. In our studies, types of stationary phases as well as types of mobile phases and contents were taken into consideration. Obtained results showed unambiguously, that the most selected is the aryl stationary phase RP Si‐NAF. It exhibited the highest separation factor (α), i.e., 1.11 for mobile phase acetonitrile/water. However, considered as the standard (reference) phase, RP Si‐C18 exhibited the maximum separation factor (α), only 1.03 for the solvent system methanol/water. Besides, when the octadecyl column was used, the retention time was three times longer, compared with the use of the analogous aryl column.
5
Krzysztof Pypowski, Iwona Uszyńska, Mariusz Kluska · Journal of Liquid Chromatography & Related Technologies · 2006 · 18 citations