Radiology · 2010 · 207 citations · 27 references
MedicineRadiologyBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyBreast AssessmentBreast ImagingBreast Lesion CharacterizationBreast TomosynthesisMedical ImagingOptical TomographyDigital Breast Tomosynthesis InterpretationFibroglandular Tissue QuantificationHemoglobin FunctionHemoglobin ImagingHemoglobin Oxygen Saturation AnalysisHemoglobin Oxygenation MeasurementOxygen SaturationRed Blood Cell Hemoglobin Concentration
PURPOSE: To explore the optical and physiologic properties of normal and lesion-bearing breasts by using a combined optical and digital breast tomosynthesis (DBT) imaging system. MATERIALS AND METHODS: Institutional review board approval and patient informed consent were obtained for this HIPAA-compliant study. Combined optical and tomosynthesis imaging analysis was performed in 189 breasts from 125 subjects (mean age, 56 years ± 13 [standard deviation]), including 138 breasts with negative findings and 51 breasts with lesions. Three-dimensional (3D) maps of total hemoglobin concentration (Hb(T)), oxygen saturation (So(2)), and tissue reduced scattering coefficients were interpreted by using the coregistered DBT images. Paired and unpaired t tests were performed between various tissue types to identify significant differences. RESULTS: The estimated average bulk Hb(T) from 138 normal breasts was 19.2 μmol/L. The corresponding mean So(2) was 0.73, within the range of values in the literature. A linear correlation (R = 0.57, P < .0001) was found between Hb(T) and the fibroglandular volume fraction derived from the 3D DBT scans. Optical reconstructions of normal breasts revealed structures corresponding to chest-wall muscle, fibroglandular, and adipose tissues in the Hb(T), So(2), and scattering images. In 26 malignant tumors of 0.6-2.5 cm in size, Hb(T) was significantly greater than that in the fibroglandular tissue of the same breast (P = .0062). Solid benign lesions (n = 17) and cysts (n = 8) had significantly lower Hb(T) contrast than did the malignant lesions (P = .025 and P = .0033, respectively). CONCLUSION: The optical and DBT images were structurally consistent. The malignant tumors and benign lesions demonstrated different Hb(T) and scattering contrasts, which can potentially be exploited to reduce the false-positive rate of conventional mammography and unnecessary biopsies.
27
Optical tomography in medical imaging
Simon Arridge · Inverse Problems · 1999 · 2.5K citations
Digital tomosynthesis in breast imaging.
Loren T. Niklason, Bradley Christian, Laura E. Niklason et al. · Radiology · 1997 · 762 citations
Imaging the body with diffuse optical tomography
David A. Boas, Dana H. Brooks, Eric L. Miller et al. · IEEE Signal Processing Magazine · 2001 · 717 citations