Computer Aided Surgery · 2004 · 74 citations · 12 references
MedicineOrthopaedic SurgeryOrthopedic SurgeryBiomechanicsJoint Replacement SurgeryOrthopedicsBiomechanical AnalysisIntraoperative NavigationJoint Motion AnalysisKnee BiomechanicsLower-limb ProstheticsOrthopedic ImagingImage-guided NavigationLower Limb Kinematic AlignmentLower Limb Mechanical AxisMechanical Axis DeviationObserver Variation In InterpretationProsthesis BiomechanicsTotal Knee Arthroplasty BiomechanicsTotal Knee Arthroplasty Navigation
OBJECTIVE: The restoration of a normal mechanical axis of the lower limb following total knee prosthesis (TKP) depends on the accuracy of the intra-operative measurement of the femoro-tibial angle. We have studied the reproducibility of intra-operative measurement of the coronal mechanical femoro-tibial axis with the OrthoPilot (Aesculap, Tuttlingen, Germany) non-image-based navigation system. MATERIAL AND METHODS: A consecutive series of 20 TKP (Aesculap SEARCH Evolution prosthesis) implanted by the same surgical team of two senior orthopedic surgeons was analyzed. They used a non-image-based navigation system that allows the mechanical axes of the femur and tibia to be defined with a kinematic analysis. The operating surgeon and assistant surgeon performed the kinematic analysis twice and once, respectively, and measured coronal mechanical femoro-tibial angles in maximal extension and at 90 degrees flexion without varus or valgus stress. RESULTS: The mean intra-observer variation in the measurement of the coronal mechanical femoro-tibial angle in maximal extension was 0.1 degrees (SD = 0.7 degrees). The mean intra-observer variation in the measurement of the coronal mechanical femoro-tibial angle at 90 degrees of knee flexion was 0.2 degrees (SD = 0.6 degrees). The mean inter-observer variation in the measurement of the coronal mechanical femoro-tibial angle in maximal extension was 0.1 degrees (SD = 0.7 degrees). The mean inter-observer variation in the measurement of the coronal mechanical femoro-tibial angle in maximal extension was 0.0 degrees (SD = 0.6 degrees). There were no significant differences and a high correlation between all paired intra- and inter-observer measurements. CONCLUSION: This system allows high reproducibility of the intra-operative measurement of the mechanical axes of the lower limb by a non-image-based kinematic registration of the hip, knee and ankle centers.
12
<i>Numerical Recipes, The Art of Scientific Computing</i>
William H. Press, Brian P. Flannery, Saul A. Teukolsky et al. · American Journal of Physics · 1987 · 10.1K citations
Numerical recipes: the art of scientific computing
W. H. Press, Brian P. Flannery, Saul A. Teukolsky et al. · Analytica Chimica Acta · 1987 · 3.3K citations