Journal of Structural Engineering · 1999 · 169 citations · 6 references
Geotechnical EngineeringStructural IntegrityEngineeringEarthquake EngineeringGeotechnical PropertyFoundation EngineeringCivil EngineeringMechanical EngineeringClaysStructural AnalysisGeomechanicsStructural Clay TileInfill PanelsStructural ApplicationStructural PerformanceStructural MechanicsSequential TestsStructural Engineering
Several bidirectional tests were performed on structural clay tile infilled steel frames to assess the interaction of in-plane and out-of-plane forces and to understand the behavior of damaged infills. Tests consisted of in-plane and out-of-plane uniform lateral load tests, out-of-plane drift tests, sequential tests (in-plane damage followed by out-of-plane loading, and out-of-plane damage followed by in-plane loading), one combined in-plane and out-of-plane test, and a seismic shake table test. Infill panels had sufficient out-of-plane stability under both inertial (uniform) loads and imposed drift loads. This stability was due to arching, or the development of in-plane membrane forces. The interaction of in-plane and out-of-plane forces was not significant, particularly at moderate levels of loading. The primary effect of sequential loading was loss of in-plane stiffness due to elimination of the diagonal cracking limit state. Under combined in-plane and out-of-plane loading, the infill remained remarkably stable, even after much damage to the masonry panel.
6
Behaviour of masonry infilled steel frames
J. L. Dawe, C. K. Seah · Canadian Journal of Civil Engineering · 1989 · 136 citations