Dynamic compression plates for Vancouver type B periprosthetic femoral fractures

Eleftherios Tsiridis, Amir Ali Narvani, John Timperley, Graham A. Gie

Acta Orthopaedica · 2005 · 62 citations · 27 references

DOIFull text

Open access

Abstract

Open reduction and internal fixation using DCPs seems to be a valid method for the treatment of postoperative periprosthetic femoral fractures with stable stem in place. If the stem is unstable, we suggest that DCPs may be used in association with femoral revision using a long stem. In cases with stable stem (B1), we are inclined to agree with other authors that additional fixation using an extramedullary cortical strut graft may be necessary to improve stability and promote final healing.

References

27