Journal of Biomedical Materials Research Part B Applied Biomaterials · 2012 · 75 citations · 40 references
MedicineOrthopaedic SurgeryOrthopedic SurgeryBiomaterialsOrthopaedic BiomaterialsOrthopedicsArthroplasty BiomechanicsBearing DesignHip BiomechanicsJoint Replacement MaterialsWear ResistanceWear-resistant MaterialsBearing WearBearingsBoundary LubricationFrictionFriction ExperimentsProsthesis Wear MechanismsWearWear Mechanics
Total hip replacement has been a successful surgical intervention for over 50 years, with the majority of bearings using a polyethylene cup. Long-term failure due to osteolysis and loosening has been widely documented and alternative bearings have been sought. A novel carbon fiber-reinforced poly-ether ether ketone (CFR-PEEK) cup was investigated through experimental friction and wear studies. Friction studies demonstrated the bearings operated in a boundary lubrication condition, with friction factors higher than those for other hip replacement bearings. The wear study was conducted with 36 mm diameter bearings tested against Biolox Delta heads for a period of 10 million cycles. The mean volumetric wear rate was 0.3 mm(3)/Mc, indicating the ceramic-on-CFR-PEEK bearing to be a very low wearing option for total hip replacement.
40
THE SWEDISH TOTAL HIP REPLACEMENT REGISTER
Henrik Malchau, Peter Herberts, Thomas Eisler et al. · Journal of Bone and Joint Surgery · 2002 · 814 citations
Squeaking in Ceramic-on-Ceramic Hips
William L. Walter, Gary O’Toole, Andrew Ellis et al. · The Journal of Arthroplasty · 2007 · 321 citations
Harry A. McKellop, Fu‐Wen Shen, Bin Lü et al. · Journal of Bone and Joint Surgery · 2000 · 262 citations