Some Errors in Linear Polarization Measurements and Their Correction

F. Mansfeld

CORROSION · 1974 · 47 citations · 1 references

Concepts

Abstract

The errors due to the use of the approximation Icorr′=B′ΔI,, where B′ depends on anodic and cathodic Tafel slopes, in commercial corrosion current meters is shown to be due to the nonlinearity of the current-potential curve in the vicinity of the corrosion potential. These errors are calculated for various combinations of Tafel slopes. It is proposed to use the relationship Icorr = κΔI, where κ depends on Tafel slopes, sign, and magnitude of polarization. The values of κ are tabulated for various combinations of Tafel slopes and polarization of +10 and -10 mV. The proposed procedure leads to correct values of corrosion currents independent of the degree of nonlinearity of the polarization curve.

References

1