Physics in Medicine and Biology · 2011 · 67 citations · 35 references
MedicineRadiation OncologyRadiologyRadiation DosimetryRadiation MeasurementTreatment PlanningImage-guided RadiotherapyIn Vivo DosimetryIonization Chamber DosimetryRadiation Dose MeasurementRadiation TherapyStereotactic RadiotherapyBeam CollimationDosimetric CalibrationOrthovoltage RadiotherapyPercentage Depth DoseReference Beam CalibrationReference Beam DosimetryStereotactic Ablative RadiotherapyStereotactic Body Radiotherapy Dosimetry
Small animal irradiation provides an important tool used by preclinical studies to assess and optimize new treatment strategies such as stereotactic ablative radiotherapy. Characterization of radiation beams that are clinically and geometrically scaled for the small animal model is uniquely challenging for orthovoltage energies and minute field sizes. The irradiator employs a commercial x-ray device (XRAD 320, Precision x-ray, Inc.) with a custom collimation system to produce 1-10 mm diameter beams and a 50 mm reference beam. Absolute calibrations were performed using the AAPM TG-61 methodology. Beam's half-value layer (HVL) and timer error were measured with an ionization chamber. Percent depth dose (PDD), output factors (OFs) and off-axis ratios were measured using radiochromic film, a diode and a pinpoint ionization chamber at 19.76 and 24.76 cm source-to-surface distance (SSD). PDD measurements were also compared with Monte Carlo (MC) simulations. In-air and in-water absolute calibrations for the reference 50 mm diameter collimator at 19.76 cm SSD were measured as 20.96 and 20.79 Gy min(-1), respectively, agreeing within 0.8%. The HVL at 250 kVp and 15 mAs was measured to be 0.45 mm Cu. The reference field PDD MC simulation results agree with measured data within 3.5%. PDD data demonstrate typical increased penetration with increasing field size and SSD. For collimators larger than 5 mm in diameter, OFs measured using film, an ion chamber and a diode were within 3% agreement.
35
Stereotactic Body Radiation Therapy for Inoperable Early Stage Lung Cancer
Robert Timmerman · JAMA · 2010 · 2.5K citations · Full text
Robert Timmerman, Ronald C. McGarry, Constantin T. Yiannoutsos et al. · Journal of Clinical Oncology · 2006 · 1.5K citations · Full text
Medicine, Radiation Oncology, Clinical Radiation Oncology +16
AAPM protocol for 40–300 kV x‐ray beam dosimetry in radiotherapy and radiobiology
Chao Ma, C Coffey, L DeWerd et al. · Medical Physics · 2001 · 819 citations · Full text