Publication | Open Access
A Sub-PPM Automated 1-10 Volt DC Measuring System
20
Citations
1
References
1985
Year
An automated measuring system has been developed for measuring arbitrary-voltage references in the range of 1-10 V with an inherent measurement accuracy of ± 0.22 ppm (3¿). This paper discusses the design and uncertainty analysis of the system and presents data obtained on a Zener voltage reference.