Physics in Medicine and Biology · 1980 · 54 citations · 7 references
MedicineRadiologyDiagnostic RadiologyRadiation DetectionRadiation DosimetryAbsorbed DoseMonte Carlo DosimetryPhoton DosimetryRadiation Dose MeasurementX-ray DetectionX-ray DetectorsBreast Dose CalculationBreast DosimetryMonte Carlo Dose SimulationRadiation Dose AssessmentRadiation Dose EstimationRadiation Dose ReductionX-ray DosimetryX-ray Spectra
A Monte Carlo computer program has been developed for the computation of integral radiation dose to the breast in xeromammography. The results are given in terms of the integral dose per unit area of the breast per unit incident exposure. The calculations have been made for monoenergetic incident photons and the results integrated over a variety of X-ray spectra from both tungsten and molybdenum targets. This range incorporates qualities used in conventional and xeromammography. The program includes the selenium plate used in xeroradiography; the energy absorbed in this detector has also been investigated. The latter calculations have been used to predict relative values of exposure and of integral dose to the breast for xeromammograms taken at various radiation qualities. The results have been applied to recent work on the reduction of patient exposure in xeromammography by the addition of aluminium filters to the X-ray beam.
7
X-Ray Fluorescence Yields, Auger, and Coster-Kronig Transition Probabilities
W. Bambynek, Bernd Crasemann, R.W. Fink et al. · Reviews of Modern Physics · 1972 · 1.9K citations
Absorbed Radiation Dose in Mammography
G. Richard Hammerstein, Daniel W. Miller, D. R. White et al. · Radiology · 1979 · 548 citations
Epoxy resin based tissue substitutes
D. R. White, R. J. Martin, R. Darlison · British Journal of Radiology · 1977 · 252 citations
Radiation exposure to the patient in xeroradiography
J. W. Boag, A. J. Stacey, R. Davis · British Journal of Radiology · 1976 · 39 citations