Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · 2008 · 18 citations · 13 references
EngineeringBiomedical EngineeringRadiologyBiomedical ImagingDiagnostic ImagingInterventional RadiologyDetector TechnologyFluoroscopic ImagingImage-guided InterventionMedical ImagingMedical Imaging InstrumentationX-ray DetectorsComputed Tomography InstrumentationDetector Spatial ResolutionDetectorsFluoroscopic GuidanceHigh-resolution X-ray DetectorsImage-guided Endovascular TherapyIn Vivo ImagingInterventional Angiography
New advances in catheter technology and remote actuation for minimally invasive procedures are continuously increasing the demand for better x-ray imaging technology. The new x-ray high-sensitivity Micro-Angiographic Fluoroscope (HS-MAF) detector offers high resolution and real-time image-guided capabilities which are unique when compared with commercially available detectors. This detector consists of a 300 μm CsI input phosphor coupled to a dual stage GEN2 micro-channel plate light image intensifier (LII), followed by minifying fiber-optic taper coupled to a CCD chip. The HS-MAF detector image array is 1024×1024 pixels, with a 12 bit depth capable of imaging at 30 frames per second. The detector has a round field of view with 4 cm diameter and 35 microns pixels. The LII has a large variable gain which allows usage of the detector at very low exposures characteristic of fluoroscopic ranges while maintaining very good image quality. The custom acquisition program allows real-time image display and data storage. We designed a set of in-vivo experimental interventions in which placement of specially designed endovascular stents were evaluated with the new detector and with a standard x-ray image intensifier (XII). Capabilities such fluoroscopy, angiography and ROI-CT reconstruction using rotational angiography data were implemented and verified. The images obtained during interventions under radiographic control with the HS-MAF detector were superior to those with the XII. In general, the device feature markers, the device structures, and the vessel geometry were better identified with the new detector. High-resolution detectors such as HS-MAF can vastly improve the accuracy of localization and tracking of devices such stents or catheters.
13
L.A. Feldkamp, L. C. Davis, J. W. Kress · Journal of the Optical Society of America A · 1984 · 6.2K citations
Heart Disease and Stroke Statistics—2008 Update
Wayne D. Rosamond, Katherine M. Flegal, Karen L. Furie et al. · Circulation · 2007 · 3.7K citations
Medicine, Cardiology, Health Policy +17
Creation of Saccular Aneurysms in the Rabbit
Talissa A. Altes, Harry J. Cloft, John G. Short et al. · American Journal of Roentgenology · 2000 · 211 citations
Medicine, Neurosurgery, Surgery +13
Endovascular image‐guided interventions (EIGIs)
Stephen Rudin, Daniel R. Bednarek, Kenneth R. Hoffmann · Medical Physics · 2007 · 61 citations · Full text