The Journal of Physical Chemistry B · 2003 · 472 citations · 62 references
EngineeringBioengineeringBiotechnologyBiosensorsNanomaterialsSensorsNanomaterial-based BiosensorsNanoparticle SurfacesNanosensorsOptical BiosensingOptical BiosensorsSurface Functionalization Of NanomaterialsLocalized Surface Plasmon ResonanceLocalized Surface Plasmon Resonance BiosensorsNanomaterial-based Optical BiosensorsNanoparticle Surface FunctionalizationNanoparticlesNormalized Response SpectraOptical NanobiosensorsSaturation
The shift in the extinction maximum, λ max, of the localized surface plasmon resonance (LSPR) spectrum of triangular Ag nanoparticles (∼90 nm wide and 50 nm high) is used to probe the interaction between a surface-confined antigen, biotin (B), and a solution-phase antibody, anti-biotin (AB). Exposure of biotin-functionalized Ag nanotriangles to 7 × 10 -7 M < [AB] < 7 × 10 -6 M caused a ∼38 nm red-shift in the LSPR λ max . The experimental normalized response of the LSPR λ max shift, (Δ R /Δ R max ), versus [AB] was measured over the concentration range 7 × 10 -10 M < [AB] < 7 × 10 -6 M. Comparison of the experimental data with the theoretical normalized response for a 1:1 binding model yielded values for the saturation response, Δ R max = 38.0 nm, the surface-confined thermodynamic binding constant, K a,surf = 4.5 × 10 7 M -1, and the limit of detection (LOD) < 7 × 10 -10 M. The experimental saturation response was interpreted in terms of a closest-packed structural model for the surface B−AB complex in which the long axis of AB, l AB = 15 nm, is oriented horizontally and the short axis, h AB = 4 nm is oriented vertically to the nanoparticle surface. This model yields a quantitative response for the saturation response, Δ R max = 40.6 nm, in good agreement with experiment, Δ R max = 38.0 nm. An atomic force microscopy (AFM) study supports this interpretation. In addition, major improvements in the LSPR nanobiosensor are reported. The LSPR nanobiosensor substrate was changed from glass to mica, and a surfactant, Triton X-100, was used in the nanosphere lithography fabrication procedure. These changes increased the adhesion of the Ag nanotriangles by a factor of 9 as determined by AFM normal force studies. The improved adhesion of Ag nanotriangles now enables the study of the B−AB immunoassay in a physiologically relevant fluid environment as well as in real-time. These results represent important new steps in the development of the LSPR nanosensor for applications in medical diagnostics, biomedical research, and environmental science.
62
Semiconductor Clusters, Nanocrystals, and Quantum Dots
A. Paul Alivisatos · Science · 1996 · 11.4K citations
Nanowire Nanosensors for Highly Sensitive and Selective Detection of Biological and Chemical Species
Yi Cui, Qingqiao Wei, Hongkun Park et al. · Science · 2001 · 5.8K citations
Surface Plasmon Spectroscopy of Nanosized Metal Particles
Paul Mulvaney · Langmuir · 1996 · 3.7K citations