Time-of-flight detectors with improved timing performance for isochronous mass measurements at the CSRe

W. Zhang, X. L. Tu, M. Wang, Yuxiang Zhang, Hu Xu, Yu. A. Litvinov, K. Blaum, R.J. Chen, Xiangcheng Chen, Chuancheng Fu,

Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · 2014 · 47 citations · 19 references

DOIFull text

Open access

Concepts

Abstract

In isochronous mass spectrometry (IMS) established in heavy-ion storage rings the revolution times of the stored secondary ions should be independent of their velocity spread. However, this isochronous condition is fulfilled only in first order and in a small range of revolution times. To correct for the non-isochronicity an additional measure of the velocity or magnetic rigidity of each stored ion is required. For this purpose two new time-of-flight (TOF) detectors were installed in a straight section of the experimental Cooler Storage Ring CSRe in Lanzhou. The performance of the new time-of-flight (TOF) detectors, which is crucial for the achievable efficiencies and mass resolving power, was significantly improved. The time resolution of the TOF detector in offline tests was σ = 18.5 ± 2 ps . The detector setup was put into operation with a stable beam of 78 Kr.

References