Transferred power and efficiency of a coupled-resonator WPT system

Ikuo Awai, Toshio Ishizaki

2012 · 26 citations · 1 references

Concepts

Abstract

A coupled-resonator WPT system is analyzed in terms of transferred power and transfer efficiency. Quality factor (f <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">m</sub> ) of the coupled resonators is defined by the product of the coupling coefficient (k) and unloaded Q (Q <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1</sub> , Q <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> ) of the resonators. Though it is well known that the maximum value of transfer efficiency is determined only by f <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">m</sub> , its condition has been unrealistic. The present paper gives a new expression that is not only far more realistic but also physically acceptable. In addition, the operating frequency selection method for the case of double peak response due to the over-coupling is proposed. A widely accepted method of the peak preference is criticized.

References

1