Fatigue & Fracture of Engineering Materials & Structures · 1979 · 254 citations · 12 references
Natural SciencesMaterials EngineeringMaterials ScienceMaterials CharacterizationMechanical Behavior Of MaterialsStructural MaterialsDamage MechanicsFatigueFracture MechanicsFracture PropagationFracture ToughnessStress-strain BehaviorCrack ClosureCrack GrowthCrack Growth KineticsCrack Growth RateFatigue Crack GrowthGrowth RatesTitanium AlloysTitanium Materials
Abstract— Fatigue crack closure in commercial titanium has been investigated by examining the crack profile using a two‐stage replica technique and by monitoring the crack raouth opening displacement. The replicas show that when closure occurs the crack does not close back from the crack tip but at discrete contact points along the crack faces. The observed closure mechanism is therefore quite different from the generally accepted model. Assuming that the contact points wedge the crack open, the stress intensity at the minimum load is greater than expected and the range of the stress intensity is effectively reduced. Also, it was found that the crack growth rates measured in the range 0·05 ≦ R ≦ 0·7 showed a singular dependence on the parameter Δθ which for SEN specimens approximates to the change in angle subtended by the crack faces. It is therefore suggested that there is a direct link between Δθ and the effective stress intensity amplitude.