International Journal of Clothing Science and Technology · 2004 · 11 citations · 5 references
EngineeringToxicologyFire Protection EngineeringOccupational Injury PreventionWorkplace Injury PreventionClothing InsulationFire PreventionFire SafetyFire-resistant MaterialsSkin ProtectionThermal Protection MaterialsChemical Protective ClothingFire-retardant FinishesFireproofing MaterialsFlame Retardant FinishingFlame Retardant TreatmentsFlame RetardantsFlash Fire ProtectionProtective Clothing
During conflict, Royal Navy personnel wear a two‐ply flame‐retardant (FR) “action coverall” (AC) and “anti‐flash” (AF) hood and gloves, made from Proban (Albright & Wilson's registered trademark) treated cotton. It is a widely held belief that extended wear, and repeated washing damages the Proban ® FR finish making the garments more susceptible to ignition if exposed to flame. To examine this, new and used AC and AF were exposed up to 10 s on a flame manikin. The examples of used AC and AF had been worn for approximately 56 days and washed 20 times over a 12 week period at sea. For flame challenges up to 10 s, much greater than expected in a fuel explosion, the protection afforded by the used clothing was as good as for the new clothing, with some evidence that protection had improved. It is concluded that the Proban ® FR treatment was not damaged by wear or washing.
5
Burn injury and prevention in the Lebanon War, 1982.
Raphael Shafir, E Nili, Ron Kedem · PubMed · 1984 · 15 citations