Dryout in a Boiling Channel under Oscillatory Flow Condition.

Hisashi Umekawa, Mamoru Ozawa, Akira Miyazaki, Kaichiro Mishima, Takashi Hibiki

JSME International Journal Series B · 1996 · 14 citations · 4 references

DOIFull text

Open access

Concepts

Abstract

Premature dryout due to flow oscillation is a very important factor in designing boiling systems. The flow oscillation depends, in general, on system size and/or configuration, and therefore the relationship between the premature dryout and the flow oscillation has not been fully understood so far. In this investigation, a CHF experiment in a forced flow boiling channel under the oscillatory flow condition has been conducted. Numerical simulation has also been conducted based on the lumped-parameter model of the boiling channel. The simulation well represents the transient behavior of the dryout under the oscillatory flow condition.

References

4