Computer Methods in Biomechanics & Biomedical Engineering · 2011 · 86 citations · 28 references
MedicineOrthopaedic SurgeryOrthopedic SurgeryBiomechanicsOrthopedic BiomechanicsOrthopedicsCartilage MechanicsComputational BiomechanicsContact MechanicsJoint BiomechanicsJoint MechanicsMusculoskeletal BiomechanicsBiomechanical Contact MechanicsContact Pressure AnalysisHertzian ContactHertzian Contact MechanicsHertzian Contact TheoryJoint Contact MechanicsKnee Contact MechanicsKnee Joint Mechanics
Combining musculoskeletal simulations with anatomical joint models capable of predicting cartilage contact mechanics would provide a valuable tool for studying the relationships between muscle force and cartilage loading. As a step towards producing multibody musculoskeletal models that include representation of cartilage tissue mechanics, this research developed a subject-specific multibody knee model that represented the tibia plateau cartilage as discrete rigid bodies that interacted with the femur through deformable contacts. Parameters for the compliant contact law were derived using three methods: (1) simplified Hertzian contact theory, (2) simplified elastic foundation contact theory and (3) parameter optimisation from a finite element (FE) solution. The contact parameters and contact friction were evaluated during a simulated walk in a virtual dynamic knee simulator, and the resulting kinematics were compared with measured in vitro kinematics. The effects on predicted contact pressures and cartilage-bone interface shear forces during the simulated walk were also evaluated. The compliant contact stiffness parameters had a statistically significant effect on predicted contact pressures as well as all tibio-femoral motions except flexion-extension. The contact friction was not statistically significant to contact pressures, but was statistically significant to medial-lateral translation and all rotations except flexion-extension. The magnitude of kinematic differences between model formulations was relatively small, but contact pressure predictions were sensitive to model formulation. The developed multibody knee model was computationally efficient and had a computation time 283 times faster than a FE simulation using the same geometries and boundary conditions.
28
Biomechanics of the musculo-skeletal system
Choice Reviews Online · 1995 · 541 citations
Articular contact in a three-dimensional model of the knee
Leendert Blankevoort, Jan Herman Kuiper, R. Huiskes et al. · Journal of Biomechanics · 1991 · 529 citations · Full text