Sensors · 2014 · 38 citations · 25 references
Natural SciencesDiagnostic SciencesAcousticsUltrasonographyUltrasoundCrack AssessmentDiagnostic UltrasonographyFracture MechanicsStructural Health MonitoringTransducer TechnologyUltrasonicsCrack DetectionCracksFourier TransformFrequency Spectrum AnalysisLongitudinal WavesUltrasonic Nondestructive EvaluationUltrasonic TestingUltrasonic Waves
Ultrasonic is one of the most common uses of a non-destructive evaluation method for crack detection and characterization. The effectiveness of the acoustic-ultrasound Structural Health Monitoring (SHM) technique for the determination of the depth of the surface crack was presented. A method for ultrasonic sizing of surface cracks combined with the time domain and frequency spectrum was adopted. The ultrasonic frequency spectrum was obtained by Fourier transform technique. A series of test specimens with various depths of surface crack ranging from 1 mm to 8 mm was fabricated. The depth of the surface crack was evaluated using the pulse-echo technique. In this work, three different longitudinal waves with frequencies of 2.25 MHz, 5 MHz and 10 MHz were employed to investigate the effect of frequency on the sizing detection of surface cracks. Reasonable accuracies were achieved with measurement errors less than 7%.
25
The use of Lamb waves for the long range inspection of large structures
P. Cawley, David Alleyne · Ultrasonics · 1996 · 353 citations
Quantitative nondestructive evaluation
J. D. Achenbach · International Journal of Solids and Structures · 2000 · 344 citations
A. Abbate, Jia Jin Koay, J. Frankel et al. · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · 1997 · 278 citations