Journal of Fluids Engineering · 1997 · 25 citations · 0 references
EngineeringIndustrial EngineeringComputational Fluid DynamicsFluid DynamicsProcess ControlExperimental Fluid MechanicsFlow MeasurementNozzle DesignNozzle FlowPneumatic ActuationPneumatic SystemsAirflow MonitoringAirflow RegulationInjection Nozzle DesignJet ImpingementNozzle GeometryNumerical Flow SimulationPneumatic Control SystemsStatic Pressure
The present paper describes an experimental investigation of the various parameters affecting the operation of industrial pneumatic controllers based on the jet nozzle principle. A test rig was built to monitor supply pressure, air temperature, airflow characteristics, and the static pressure distribution over the flat plate on which the jet impinges. The results demonstrate the existence of a low pressure, separated flow zone, subject to fouling, which subsequently was eliminated by appropriate changes of the injection nozzle geometry. The previous experimental findings were also confirmed by numerical simulation of the flow. Experimental results also show that the internal diameter of the regulator, situated inside the measuring branch, has an important influence on the sensitivity of the apparatus, as well as influencing its range.