The Analyst · 2013 · 51 citations · 30 references
EngineeringBioengineeringBiomedical EngineeringBiomemsInfertilityReproductive BiologyMicrofluidic DevicesMicrofluidicsSemen AnalysisSperm BiologySperm Concentration AssessmentSperm Motility AssessmentMicrofluidic Chip DesignMicrofluidic Device DesignMicrofluidic Sperm CountingMicrofluidic Sperm SortingMotility Analysis ChambersSemen Sample HandlingSemen Sample PreparationSperm Function Assessment
A major reason for infertility is due to male factors, including the quality of spermatozoa, which is a primary factor and often difficult to assess, particularly the total sperm concentration and its motile percentage. This work presents a simple microfluidic device to assess sperm quality by quantifying both total and motile sperm counts. The key design feature of the microfluidic device is two channels separated by a permeative phase-guide structure, where one channel is filled with raw semen and the other with pure buffer. The semen sample was allowed to reach equilibrium in both chambers, whereas non-motile sperms remained in the original channel, and roughly half of the motile sperms would swim across the phase-guide barrier into the buffer channel. Sperms in each channel agglomerated into pellets after centrifugation, with the corresponding area representing total and motile sperm concentrations. Total sperm concentration up to 10(8) sperms per ml and motile percentage in the range of 10-70% were tested, encompassing the cutoff value of 40% stated by World Health Organization standards. Results from patient samples show compact and robust pellets after centrifugation. Comparison of total sperm concentration between the microfluidic device and the Makler chamber reveal they agree within 5% and show strong correlation, with a coefficient of determination of R(2) = 0.97. Motile sperm count between the microfluidic device and the Makler chamber agrees within 5%, with a coefficient of determination of R(2) = 0.84. Comparison of results from the Makler Chamber, sperm quality analyzer, and the microfluidic device revealed that results from the microfluidic device agree well with the Makler chamber. The sperm microfluidic chip analyzes both total and motile sperm concentrations in one spin, is accurate and easy to use, and should enable sperm quality analysis with ease.
30
Improving the Density of Jammed Disordered Packings Using Ellipsoids
Aleksandar Donev, Ibrahim Cisse, David Sachs et al. · Science · 2004 · 1.3K citations
Population study of causes, treatment, and outcome of infertility.
M.G.R. Hull, Cathryn Glazener, N. J. Kelly et al. · BMJ · 1985 · 1.1K citations · Full text
Medicine, Gynecology, Obstetrics +17
Significance of sperm characteristics in the evaluation of male infertility
Kiran P. Nallella, Rakesh Sharma, Nabil Aziz et al. · Fertility and Sterility · 2006 · 288 citations · Full text