Science · 1974 · 36 citations · 8 references
EngineeringEnvironmental EngineeringEnvironmental SciencesAir PollutionAtmospheric ChemistryAtmospheric ScienceAir PollutantsAir Pollution InstrumentationAir Pollution MeasurementAir QualityAmbient Air QualityGas SensorsAir Quality Monitoring InstrumentsAtmospheric MonitoringAtmospheric Pollutant MonitoringAtmospheric PressureNitric OxideOzone MeasurementRemote Sensing Of Air PollutantsSulfur Dioxide Ambient Concentrations
An infrared heterodyne radiometer with a spectral resolution of 0.04 reciprocal centimeters has been used to remotely detect samples of ozone, sulfur dioxide, ammonia, and ethylene at room temperature, and samples of nitric oxide at 390K. Each gas was observed in a background of nitrogen or oxygen at atmospheric pressure. Sensitivities to some of these gases are adequate for detection of ambient concentrations as low as a few parts per billion.
8
Detection of Air Pollutants with Tunable Diode Lasers
E. D. Hinkley, Paul Kelley · Science · 1971 · 177 citations
Engineering, Electrical Engineering, Environmental Sciences +17