Surface Area Loss of Platinum Supported on Carbon in Phosphoric Acid Electrolyte

G. A. Gruver, R. F. Pascoe, H. Russell Kunz

Journal of The Electrochemical Society · 1980 · 86 citations · 0 references

Concepts

Abstract

An experimental study was conducted to determine the surface area loss of platinum supported on carbon in a 191°C phosphoric acid fuel cell environment and to define the mechanism for this process. The surface area was found to decline rapidly initially, but remains above 20 m2/g for 20,000 hr, the longest time period investigated. A study of the effect of operating potential, transmission electron microscope studies of electrodes, and Pt deposited on a carbon film, and the results of other previous studies indicate that crystallite migration and coalescence are the major mode by which Pt surface area is lost in this situation.