Influence of Cross-Linking on Performance of Radiation-Grafted and Sulfonated FEP 25 Membranes in H[sub 2]-O[sub 2] PEFC

Thomas J. Schmidt, K. Simbeck, Günther G. Scherer

Journal of The Electrochemical Society · 2004 · 54 citations · 15 references

Concepts

Abstract

This work describes the influence of cross-linking on the performance of radiation-grafted and sulfonated FEP 25 membranes in H<sub>2</sub>-O<sub>2</sub> polymer electrolyte fuel cells (PEFCs). This study shows H<sub>2</sub>-O <sub>2</sub> fuel cell tests with varying cross-linked membranes [0, 2, 5, 10, and 20% divinyl benzene (DVB) in the grafting solution]. Under the membrane preparation conditions, the optimum DVB concentration was found to be 10% within the applied range with respect to both fuel cell performance and membrane stability. We could show by electrochemical impedance spectroscopy that the cell performance is significantly influenced by both the membrane resistance, which is increasing with increasing cross-linking, and the cathodic polarization resistance, which was found to decrease with increasing cross-linking. Due to these counteracting effects, the cell performance is optimized with a membrane with 10% DVB in the grafting solution. The stability of the varying cross-linked membrane also significantly improves by cross-linking with 10 or even 20% DVB. Whereas the non- or low-cross-linked membranes are subject to strong deterioration with lifetimes below 500 h of operation, we demonstrate high stability with a membrane with 10% DVB over 2500 h operated in the temperature range between 60 and 80°C.

References

15