Scandinavian Journal of Clinical and Laboratory Investigation · 1964 · 374 citations · 4 references
MedicineGynecologyHematologyIron Metabolism DisordersMenstrual DisordersWomen's HealthAnemiaBlood Loss AssessmentIron DeficiencyIron Deficiency DisordersMenstrual CycleQuantification Of Blood LossBlood Collection EquipmentBlood Sample CollectionIron Deficiency AssessmentIron Deficiency DiagnosisMenstrual Blood Loss AssessmentMenstrual Blood Loss MeasurementMenstrual Iron LossQuantitative Blood Loss Measurement
There is a need for a simple and reliable method of measuring menstrual blood loss. Such measurements could be useful in clinical practice and in basic studies. A simple chemical method for quantifying blood loss is described. The method involves extracting tampons and towels used in blood collection for 20 hours with a sodium hydroxide solution. This method which has been used for 2 years is thought to be accurate and convenient. The method should be useful in determining the cause of iron deficiency anemia and for studies on the effect of various treatments on excessive menstrual bleeding.
4
MEASUREMENT WITH 51Cr OF RED-CELL LOSS IN MENORRHAGIA
G. Rankin, N. Veall, R. G. Huntsman et al. · The Lancet · 1962 · 23 citations
Medicine, Gynecology, Physiology +5