BJOG An International Journal of Obstetrics & Gynaecology · 2008 · 60 citations · 27 references
MedicineGynecologyObstetricsObstetric UltrasoundUltrasonographyUltrasoundEarly Pregnancy AssessmentObstetric UltrasonographyThree-dimensional UltrasonographyThree-dimensional UltrasoundUltrasound ImagingAutomated Volume AnalysisIntraclass CorrelationObstetric Three-dimensional UltrasonographyObstetric Three-dimensional UltrasoundQuantitative Volume MeasurementThree-dimensional Fetal UltrasoundThree-dimensional Ultrasound QuantificationVolume Calculation
OBJECTIVE: To investigate accuracy and reliability of four different ultrasound-related volume-measuring methods. DESIGN: Observational study. SETTING: Both in vitro and in vivo. POPULATION OR SAMPLE: Ten phantoms for in vitro measurements and 28 pregnancies with gestational ages ranging from 6 to 11 weeks for in vivo measurements were included. METHODS: Three-dimensional (3D) ultrasound images of phantoms (with known variable contents) and yolk sacs were used to calculate volumes using four different methods: Virtual Organ Computed-Aided AnaLysis (VOCAL), inversion mode, Sono Automatic Volume Calculation (SonoAVC) and V-Scope. V-Scope is a newly developed 3D volume visualisation application using a Barco I-Space virtual reality system. Intra- and interobserver agreement was established by calculating intraclass correlation coefficients (ICC). MAIN OUTCOME MEASURE: Evaluation of accuracy and reliability by comparing the different techniques with true volumes (in vitro) and with each other (in vitro and in vivo). RESULTS: In the in vitro study, volume measurements by VOCAL, inversion mode and V-Scope proved to be accurate. SonoAVC measurements resulted in a substantial systematic underestimation. Correlation coefficients of measured versus true volumes were excellent in all four techniques. For all techniques, an intra- and interobserver agreement of at least 0.91 was found. Yolk sac measurements by the different techniques proved to be highly correlated (ICCs>0.91). CONCLUSIONS: We demonstrated that VOCAL, inversion mode and V-Scope can all be used to measure volumes of hypoechoic structures. The newly introduced V-Scope application proved to be accurate and reliable.
27
A H BECKETT, M ROWLAND, P TURNER · The Lancet · 1965 · 16.9K citations
Edward J. Pavlik, Paul D. DePriest, Holly H. Gallion et al. · Gynecologic Oncology · 2000 · 286 citations
Medicine, Endocrinology, Gynecology +12
Nick Raine‐Fenning, J. Clewes, N.R. Kendall et al. · Ultrasound in Obstetrics and Gynecology · 2003 · 228 citations · Full text